Wuhan Solar Sunrise Photoelectric technology Co., LtdChina Professional Solar Cell Tester, Solar Module Tester, EL Tester manufacturer |
Portable IV tester
Product Description:
OVERVIEW:
Portable Solar IV Testers are used mostly for testing I-V characteristic of outdoor solar arrays/modules/cells. As test tools, necessary for power station building enterprises, quality inspection activities, manufacturers as well as science research institutions, they can conveniently and quickly test these arrays/modules/cells for their operating properties in the sunlight, and also can provide test services for design, acceptance and maintenance of solar power stations. These products, attached with probes for detecting ambient temperature, solar panel temperature, solar irradiance and etc., can fully record testing environment status. With portable design applied for their host, the testers are dust-proof, and splattering water resistant, and provide color LED display, visible in highly illumination or sunlight, which is suitable for demands for field work. The results are directly visual due to the built-in Windows interface, familiar to users, which provide users an excellent experience with operation
FEATURES:
1.Wireless connection between the host and solar irradiance meter, provides wireless communication to maximum 100 m, enabling tests more conveniently and quickly.
2.Offering patented solar irradiance meter and temperature probe fixtures for ease of mounting these probes on the solar panels.
3.The unique bar-code scanning functions for smart identification of the PV modules.
4.Color LED display, visible in highly illumination or sunlight, and touch screen plus keyboard operation with various peripheral interfaces provide an uncommon experience with operations. The internal memory of the tester can save above 2000 test waveforms and support expansion for memory volume due to built-in SD card socket.
5.WINCE graphics system with multi-lingual options and friendly designed menu, allowing you to learn various functions on the tester rapidly.
6.Offer users with analysis software that permits you to copy data saved on the tester to the PC for analysis and print-out through the user terminal software via an USB data cable.
7.I-V characteristic testing for outdoor low irradiance, provides corrections for standard test conditions (STC) We can provide metering services and metering certificate, if users need.
8.Built-in abundant database of correction models for PV modules, covering products of mostly solar module manufacturers. Additionally, for conversions and comparisons among results for reference, comprehensive parameter setting functions are offered for users, thus, it is easy for them to add test correction models by hand.
9.High voltage isolated source supply designed internally, ensuring reliable security for users. Wider voltage testing range allow testing for maximum open circuit voltage to 1000 V, and also the testers have functions for PV array testing up to 10kW
10.Function for automatic switching measurement range, with protection from overvoltage, and automatic continuous testing functions that can be set.
BASIC PARAMETERS
Probe box unit
|
Ambient Test Temperature Range
|
-30--100 ℃
|
Cell Test Temperature Range
|
-30--100 ℃
|
|
Temperature Test Accuracy
|
±0.1℃
|
|
Irradiance Test Range
|
0~4000W/m2
|
|
Irradiance Test Accuracy
|
Better than ±0.5%rdg
|
|
Communication Interfaces With The Host
|
RS232 series interface, Bluetooth
|
|
Length × Width × Height
|
166mm×83mm×33mm
|
|
Weight
|
450g
|
|
Power Supply
|
4 pieces of AAA battery
|
|
Host
|
Powering Mode
|
build-in lithium battery/power adapter
|
Battery Type
|
14.8V/4400mAH
|
|
Power-On Time
|
15 hours replaceable reserve battery for
longer stand-by time
|
|
Length × Width × Height
|
296×186×75mm
|
|
Weight
|
2.3kg
|
|
Operating Temperature
|
-10℃~50℃
|
|
Humidity
|
5--95%RH
|
Notice: The irradiance test accuracy will be varied due to different atmospheric conditions and surrounding environment. The accuracy parameter is measured by an AAA grade solar simulator with AM1.5 spectral distribution and irradiance not
less than 700W/m2.
SPECIFICATIONS:
Parameters
|
PIV-1
|
PIV-2 / PIV-2A
|
Voltage Test Range
|
5~1000V
(>15V at open
Circuit)
|
0~50V
0~200V
(>5V at open
Circuit)
|
Voltage Test Precision
|
0.1V
|
0.01V
|
Voltage Test Accuracy
|
±1%±0.2V
|
±0.5%±0.1V
|
Current Test Range
|
0.1~12A
|
0.01~10A
0.01~20A
|
Current Test Precision
|
0.001A
|
0.001A
|
Current Test Accuracy
|
±1%±0.02A
|
±0.5%±0.01A
|
Max Power Test Repeatability
|
±1%±5W
|
±0.5%±1W
|
Max Power Test Range
|
50W~10kW
|
0W~500W
|
Max Power Test Accuracy After
During Transition To STC
|
better than±5%±1W
|
better than±5%±1W
|
1. Notice: Measured at 25 STC(standard test conditions).
2.Notice: Measured at AM1.5 spectral distribution and irradiance not less than 700W/m2.Atlab, the value is generally within 2% Please perform the field measurements in stabilized sunlight conditions,and ensure that irradiance probe and temperature probe are mounted firmly, otherwise, higher conversion error will be caused due to irradiance and temperature measurement deviations.